DDS63 DDSF63 DSSY61 DSS63-Y
DTS63 LB4A LB4S Back to Meter Home page

Single - Phase Watt - Hour Meter


Product ID: LB4-S
Click here for A Base type : Model LB4-A

    The LB4-S single-phase watt-hour meter is the latest development in the induction type meters. The meter has been designed in a modular construction allowing for fewer components with the benefits of reduced cost and increased reliability. Servicing costs have been kept to a minimum due to the construction design, and the wide measuring range ensures accurate measurement at both low and high loads.
   The LB4-S meter enables electricity supply authorities to install the meter with total confidence a long and trouble-free service life is guaranteed by a state of art design concept.
Excellent performance in high peak loads, while at the same time accurately recording low consumption at off-peak periods are standard task for our meters.






The specialized finishing of components, and high stability of the brake magnets, the non-lubricating register mechanism, the robust measuring assembly and the high strength at continuous and surge over voltage stresses are the outstanding characteristics ou or meter.
   The LB4-S meter has been designed and manufactured in compliance with IEC521 and BS5685.
Specifications:
  • Type of connection: Direct or CT
  • Standard reference volt Uref. (V): 120/240
  • Optional reference voltage (V):110, 120, 127, 230, 240, 250
  • Standard frequency (Hz): 50 or 60
  • Torque at Uref. Load. (10^-5Nm): 40
  • Current circuit consumption at nominal charge (W): /=2.5
  • Voltage circuit consumption at nominal charge (Va; W): /=2; /=7
  • Starting current (%load): /=0.5%ib
  • Temperature coefficient per Celsius (%/Celsius): 0.10(P.F.=1.0), 0.15(P.F.=0.5)
  • Weight of rotor (g): 23
  • Accuracy class: 2.0
  • Current loading(% basic current) (%): 300
  • Basic (max.) current (A): 5(15)10(30)15(45)20(60)
  • Rated speed (rev/min): 13.2
  • Meter constant at Uref=220V (rev/kwh): 720, 360, 240, 180
  • Current loading(% basic current) (%): 400
    • Basic (max.) current (A): 5(15)10(30)15(45)20(60)
    • Rated speed (rev/min): 13.2
    • Meter constant at Uref=220V (rev/kwh): 720, 360, 240, 180
  • Current loading(% basic current) (%): 500
    • Basic (max.) current (A) 20(100)
    • Rated speed (rev/min): 13.2
    • Meter constant at Uref=220V (rev/kwh): 180
  • Current loading(% basic current) (%): 600
    • Basic (max.) current (A): 5(30) 10(60)
    • Rated speed (rev/min): 13.2
    • Meter constant at Uref=220V (rev/kwh): 720, 360
  • Current loading(% basic current) (%): 667
    • Basic (max.) current (A): 15(100)A
    • Rated speed (rev/min): 11
    • Meter constant at Uref=220V (rev/kwh): 200
  • Ordering information:

    Minimum Order: Negotiable
    Tel: 813 685-7610 Fax: 813 685-7610 FOB: Factory